Certificate of analysis
Semax
Every released batch of Semax, with the analytical record that released it. Figures are the laboratory's measurements — where the label and the assay disagree, the assay is the number to calculate from.
- Batches published
- 01
- Current batch
- EVN-SMX-2604
- Assayed purity
- 99.66%
- Released
- 23 Apr 2026
Current batch
EVN-SMX-2604
VerifiedSigned PDF on request
Determinations
| Determination | Result | Specification | Method |
|---|---|---|---|
| Purity | 99.66% | ≥ 99.0% | RP-HPLC, UV 214 nm |
| Identity | 813.8 Da (theoretical 813.9) | Conforms to theoretical mass | ESI-MS |
| Assayed content | 99.8% of label | 95.0 – 110.0% of label | RP-HPLC against reference standard |
| Water content | 2.9% | ≤ 8.0% | Karl Fischer titration |
| Residual solvents | Acetonitrile 66 ppm; TFA below quantitation | Within USP <467> limits | Headspace GC-FID |
| Appearance | White lyophilised cake | Conforms | Visual inspection |
Assayed purity99.66%
98%Spec ≥ 99%100%
- Assayed content
- 9.98 mg / 10 mg
- Laboratory
- Meridian Analytical Laboratories
- Accreditation
- ISO/IEC 17025 accredited
- Accession
- MAL-26-04355
- Manufactured
- 9 March 2026
- Tested
- 15 April 2026
- Released
- 23 April 2026
- Retest interval
- 36 months from date of manufacture
Storage conditions
Lyophilised, −20 °C, protected from light and moisture. Sample retained under identical conditions for the duration of the retest interval.
Testing standards
The references applied
Compendial standards govern how each determination is made and what limit it is judged against. Naming them is what allows a result to be compared with one produced elsewhere.
- 01USP <1225> — Validation of compendial procedures
- 02USP <467> — Residual solvents
- 03USP <921> — Water determination
- 04ISO/IEC 17025:2017 — Testing laboratory competence
Documentation
Confirm it at the source.
Ask the desk to arrange confirmation of any Semax certificate directly with the issuing laboratory, or to retrieve an archived batch record.